  • Class A Compliance
  • Display led indicators


Part Number:
FE 1744
In Stock?
Yes! Available
Variation:
Quantity
Price:
$ USD
Total:
$ USD

The Fluke 1740 Series three-phase power quality loggers are everyday power meters for technicians who troubleshoot and analyze power quality issues. Capable of simultaneously logging up to 500 power parameters for up to 85 days and monitoring for events, these power loggers help uncover intermittent and hard-to-find power quality issues.

The Fluke 1744 is a powerful three-phase power quality logger capable of logging the most common power parameters you’ll need for power quality monitoring such as:

  • V, A, W, VA, VAR
  • Power Factor
  • Energy
  • Flicker
  • Voltage
  • THD
  • Harmonics, Interharmonics
  • Mains Signaling
  • Unbalance
  • Frequency

Apart from the Fluke 1744, the Fluke 1740 series includes two other power quality loggers: Fluke 1743 & Fluke 1745.

  • The Fluke 1743 includes the same features as the Fluke 1743 but is not capable of measuring voltage and current harmonics, interharmonics, mains signaling, unbalance and frequency.
  • The Fluke 1745 includes the same features as the Fluke 1744 but features an IP50 environmental rating, a real-time LCD display and a 5 hour UPS which is great if you need to read more data at the meter and have a longer backup battery life where there’s less chance of it getting wet.

The main difference between the 1744 and the other 2 models in the series, is the 1744 measure harmonics, unbalance or mains signaling but doesn’t have an LCD display and only has a 3 hour UPS.

The included PQ Log software quickly assesses the quality of power at the service entrance, substation, or at the load, according to the latest EN50160 standard.

Applications:

  • Disturbance analysis – Uncover root cause of equipment malfunction for later mitigation and predictive maintenance
  • Quality of service compliance – Validate incoming power quality at the service entrance
  • Power quality studies – Assess baseline power quality to validate compatibility with critical systems before installation
  • Load studies – Verify electrical system capacity before adding loads
  • Energy and power quality assessment – Validate performance of facility improvements by quantifying energy consumption, power factor, and general power quality before and after improvements

What’s Included:

  • 4 Flexible probes 15/150/1500/3000 A with 2 m cable
  • CD-ROM with PQ Log software
  • RS232 interface cable and RS232-USB adapter
  • Test leads for voltages and power supply
  • 4 black dolphin clips
  • Color localization kit
  • Carrying bag
  • Test certificate with measurement values
  • Printed English manual
  • Multi-language manual CD
  • Class A Compliance
  • Class A Compliant
  • Datalogging
  • Display leds
  • Display led indicators
  • Included CT Rating 15a/150a /3000a
  • Included CT Type flexible
  • Included CTs 4x 3000a flexible cts
  • Line Power
  • Mains Signalling
  • Min/Max/Avg
  • Number Included CTs 4
  • Report Generator
  • Root Cause Analysis
  • Single Phase
  • Software
  • Statistical Analysis
  • Three Phase
  • Transient Event Capture
  • Transient Events
  • True RMS
  • Unbalance
  • User Defined Logging
Battery Life 3s
CAT III Rating 600v
Current AC Accuracy 2% of range
Current Inputs 4
Dimensions 170 x 125 x 55 mm (6.9 x 5.1 x 2.2 in.)
IP Rating ip65
Memory 8
Sample Rate 10.24
Typical Recording Period 90
Voltage AC Accuracy 0.1% of range
Voltage Inputs 4

View graphs and generate reports with Fluke Power Quality Log software

With its easy-to-use interface, the included Power Quality Log software assists you with logger setup, enables you to verify actual measurement values quickly using the online function, and downloads data from the logger to a connected PC operating on standard Windows® operating systems. You can view the logged data in graphical and tabular form, export it to a spreadsheet, or generate a professional report with the Report Writer function.

  • For root cause analysis, different measurements such as flicker, voltage and THD can be shown in the same time plot, helping to quickly identify the cause of a disturbance.
  • Statistical summaries like EN50160 and DISDIP table provide a quick, comprehensive summary. The EN50160 overview display provides a simple display of 8 power quality parameters on one dashboard, according to the latest international power quality standard.
  • Statistical analysis of Voltage and Current harmonics over a given time period. Red bar graphs indicate issues with the grid. Other colors are warnings for pontential future issues.  Harmonics can be presented also as time plots.

© 2021 Power Tech Private Limited | Theme by Hope Group Of Companies | All Rights Reserved.