Power Tech International Group Pvt. Ltd. » Liebert Nfinity (4 – 20 kVA)
[simple_crumbs root="Home" /]

Liebert Nfinity (4 – 20 kVA)



Part Number:
In Stock?
Yes! Available
Variation:
Quantity
Price:
$ USD
Total:
$ USD

 


The Liebert Nfinity on-line UPS is a scalable system, designed with N+x parallel redundancy to provide a fault-tolerant network of power protection The Liebert Nfinity on-line UPS is a scalable system, designed with N+x parallel redundancy to provide a fault-tolerant network of power protection. The modular design of the Liebert Nfinity was devised to provide easy, user-installed upgrades as power demands grow. Configurations can be cost-effectively upgraded without re-investing in a new system or installation.

  • Allows addition of battery capacity without increasing footprint.
  • Extends backup time up to 72 hours with additional battery cabinets.
  • Upgrades for capacity or redundancy without the expense or installation downtime associated with the purchase of a new UPS.
  • Enables greater system control with remote management software.

  • Offers hot-swappable power, battery, control and display modules, allowing installation or replacement without compromising power to the load.
  • Provides redundant components at critical points of UPS operation.
  • Allows maintenance to be performed without shutdown.
  • Offers emergency power-off capability.
  • Transfers seamlessly to and from the bypass source, with patent pending intelligent bypass technology.
  • Operates with a wider input voltage window for fewer transfers to battery, saving battery wear and tear.
  • Provides compatibility with backup generator – handles frequency variations and other power fluctuations that occur during generator operation.
  • Sustains 110% of the system’s rated load for an extended period of time – the highest overload capability of any system in its class.
  • Ships as a complete, fully tested system, ready for final connection.
  • Reduces maintenance costs with modular batteries, controls and power components.
  • Allows scalability to cost effectively invest in added capacity as it is needed.
  • Ships with batteries connected and charged, reducing installation time and costs.

  • Small-to-medium-sized data centers
  • Network closets
  • VoIP
Model Number 8 Bay 12 Bay
Power Rating
Rating, VA 4, 8, 12, 16kVA 4, 8, 12, 16, 20kVA
Rating, W 2.8, 5.6, 8.4, 11.2kW 2.8, 5.6, 8.4, 11.2, 14kW
Input AC Specifications
Phase 2 2
Power Factor >0.98 >0.98
Input Frequency, Hz 60 60
Frequency Rance, Hz 40 – 70 40 – 70
Input Voltage 208/240 208/240
Input Voltage Range +10, -20 +10, -20
General Specifications
UPS Technology On-Line On-Line
Battery Specifications
Battery Test Type On-Line On-Line
Battery Technology VRLA VRLA
Output AC Specifications
Nominal Voltage 120/208 120/208
Output Waveform Sinewave Sinewave
Nominal Current, Amps 50 or 60 50 or 60
Communications
Communications Options SNMP/RS232 SNMP/RS232
Software and Cable Multilink SW & Serial Cable Multilink SW & Serial Cable
Physical Data
Unit Height, inches (mm) 40 (1,016) 54 (1,372)
Unit Depth, inches (mm) 28 (711) 28 (711)
Unit Weight, lbs. (kg) 20 (508) 20 (508)
Environmental
Operating Temperature, Minimum °F (°C) 32 (0) 32 (0)
Operating Temperature, Maximum °F (°C) 104 (40) 104(40)
Storage Temperature, Maximum °F (°C) 158 (70) 158 (70)
Relative Humidity 0% to 95%, Non Condensing 0% to 95%, Non Condensing
Operating Elevation, ft. (m) to 3,300 (1,000) to 3,300 (1,000)
Storage Elevation, ft. (m) to 40,000 (12,200) to 40,000 (12,200)
Sound Emmision/Audible Noise < 62 dBA, at 1 meter < 62 dBA, at 1 meter
Cooling Fan Cooled Fan Cooled
Agency/Certification/
Conformance
Agency Approval cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed cUL Listed, FCC Part 15, Subpart B, Class A, UL 1778, UL Listed

© 2021 Power Tech Private Limited | Theme by Hope Group Of Companies | All Rights Reserved.