Fluke 376 True-RMS 1000A AC/DC Clamp Meter with iFlex
The Fluke 376 Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms ac voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes with the fixed jaw.
18″ Flexible Current Probe
The Fluke 376 includes the new Fluke iFlex i2500-18 flexible current probe which expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
The Fluke 376 is part of Fluke’s new Clamp Meter line that includes: 381, 375, 374, 373 & 365.
Replacing the Fluke 337
The Fluke 376 clamp meter is the direct replacement for the Fluke 337 clamp meter. The Fluke 376 includes all the features of the 337, but also includes:
- CAT IV 600, CAT III 1000 V
- iFlex 2500 A AC
- 1000 V AC/DC
- mV DC
- 60 kΩ
- 1000 μF
What’s Included:
- 18-inch iFlex flexible current probe – i2500-18
- TL75 test leads
- Coated instruction card
- Safety information sheet
- Soft carrying case
- Two AA Alkaline batteries
- iFlex™ flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
- CAT IV 600 V, CAT III 1000 V safety rating
- Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement
- Three-year warranty
- Soft carrying case
Range | Resolution | Accuracy | |
AC current via jaw | 999.9 A | 0.1 A | 2 % ± 5 digits |
AC current via iFlex | 2500 A | 0.1 A | 3 % ± 5 digits |
DC current | 999.9 A | 0.1 A | 2 % ± 5 digits |
AC voltage | 1000 V | 0.1 V | 1.5 % ± 5 digits |
DC voltage | 1000 V | 0.1 mV | 1 % ± 5 digits |
Resistance | 60,000 Ω | 0.1 Ω | 1 % ± 5 digits |
Frequency | 500 Hz | 0.1 Hz | 0.5 % ± 5 digits |
Capacitance | 1000 μF | 0.1 μF | 1 % ± 4 digits |
True-rms | yes | ||
Continuity | yes | ||
Hold | yes | ||
Backlight | yes | ||
Min/Max | yes | ||
Inrush | yes | ||
Low pass filter | yes | ||
18″ iFlex Flexible Current Probe | included | ||
10″ iFlex Flexible Current Probe | optional accessory | ||
Wire capacity | 750 MCM or 2-500 MCM | ||
Safety rating | CAT III 1000 V, CAT IV 600 V |