Powerware 9125 700-6000 VA UPS
The Powerware 9125 Tower UPS combines superior backup power and power quality management with innovative features that deliver the ultimate in power protection. This compact tower UPS protects critical applications from downtime, data loss and corruption, and process interruption by providing continuous, conditioned power to all connected equipment.
The Powerware 9125 Tower UPS delivers power quality protection against the full range of power anomalies – making power-related downtime a thing of the past. A double-conversion online system, the Powerware 9125 is constantly conditioning AC output, and in the event of an outage, it transfers to backup power with zero delay. A “load segments” feature enables orderly shutdown of non-critical systems to extend battery backup power time available for critical systems.
- Double-conversion online design constantly conditions and controls AC output to assure a zero delay transferring to backup power in the event of an utility power failure
- Maximizes battery backup time for critical systems with the ability to independently control Load Segments, enabling you to manage scheduled shutdowns and sequential startups of protected loads
- Enables users to remotely reboot locked-up network equipment
- Accepts up to four “hot-swappable” Extended Battery Modules to provide additional battery backup capacity as necessary, without interrupting UPS operation and load protection
- Provides up to 3000 VA of UPS power in only two units (2U) of rack space; up to 6000 VA in 5U, to conserve valuable rack space, with tower pedestal kits, optional rack kits, and seismic kits available
- Ensures data and system integrity with LanSafe power management software that uses an intuitive, graphical interface and SNMP (Simple Network Management Protocol) to provide control and visibility over multiple UPS products
- Offers a standard RS-232 serial communications port and connectivity options available to suit any communication requirement for remote monitoring
- Offers optional PowerPass power distribution modules that include a maintenance bypass switch to upgrade or replace the UPS without interrupting power
- Ensures data integrity with free Software Suite bundle including LanSafe software, PowerVision software, and NetWatc
700 – 3000 VA | 5000/6000 VA | |||
Electrical Input | Nominal Voltage | 120 Vac, 208 – 240 Vac | 208 – 240 Vac | |
Voltage Range | 120 V: 80-144 V (without using batteries) 208/230 V: 160 – 288 V (without using batteries) |
123-208 V (without using batteries) | ||
Input Power Factor | >.95, typical | >.96 in any mode | ||
Frequency | 50/60 Hz, Auto-sensing | |||
Frequency Range | 45 – 65 Hz | 50 Hz: 47-53 Hz 60 Hz: 57-63 Hz |
||
Electrical Output | On Utility Voltage Regulation |
+/-3% of nominal | ||
On Battery Voltage Regulation |
+/-3% of nominal | |||
Efficiency | 89 – 92%, depending on load | >85% Online Mode; >90% High-efficiency Mode | ||
Frequency Regulation | ±3 Hz online; ± 1 Hz on battery | ±3 Hz online; ± 1 Hz on battery; ±3 Hz High-Efficiency Mode |
||
Load Crest Factor |
3 to 1 ratio |
|||
Battery | Internal Battery type | 9 Ah, Sealed, lead-acid; maintenance free | 7 Ah, Sealed, lead-acid; maintenance free | |
EBM Battery Type | 9 Ah, Sealed, lead-acid; maintenance free | 9 Ah, Sealed, lead-acid; maintenance free | ||
Battery Replacement | Hot-swappable internal and external batteries | |||
Recharge Time | <2 hrs. From complete discharge to 100% capacity at nominal line conditions | |||
Start-On-Battery | Allows start of UPS without utility input | |||
Communications | Serial Port | RS-232 communications port standard; optional X-slot modules available |
RS-232 and USB communications port standard; optional X-slot modules available |
|
Communications cable | 6-foot communications cable included | |||
General | Topology | True online, double-conversion | ||
Diagnostics | Full system self-test on power up | |||
UPS Bypass | Automatic on Overload or UPS failure | |||
Environmental and Safety | Safety Markings | 120 V: UL, CSA and NOM 230 V: UL, CSA, VDE, CE, S, D, N, FI, B, NOM, R 208 V: UL, CSA |
UL, cUL, VDE, CE, NOM, NYCE, GS | |
EMC Markings | FCC Class B and VCCI Class II, 3000 FCC Class A | FCC-A, VCCI-A, BSMI-A, C-Tick, CE Compliance | ||
Surge Suppression | IEEE/ANSI C62.41 Category B (formerly 587) | ANSI C62.41 Category B3, and EN61000-4-5 Level 3 Criteria B | ||
Audible Noise |
<45 dBA (on utility); <50 dBA (on battery) |
|||
Ambient operating |
0 to 40ºC (32 to 104ºF); 0 to 25ºC (32 to 77ºF) |
|||
Heat Dissipation |
2066 BTU/hr. Max |
|||
Leakage Current |
< .6mA Typical |
|||
Relative Humidity | 0 to 90%, non-condensing | 5 to 90%, non-condensing | ||
REPO Port |
NEC Code 645-11 intent and UL requirements |
|||
Network Transient Protector | In and out jack for models only or 10Base-T network cable; protection. UL497A tested | N/A |