Power Tech International Group Pvt. Ltd. » Powerware 9315 200-500 kVA / 9315 500-750 kVA UPS
[simple_crumbs root="Home" /]

Powerware 9315 200-500 kVA / 9315 500-750 kVA UPS



Part Number:
In Stock?
Yes! Available
Variation:
Quantity
Price:
$ USD
Total:
$ USD


The Powerware 9315 UPS is essential for mission-critical applications such as data centers, server farms, and transportation facilities.

In your pursuit of maximum power quality and availability, the Powerware 9315 UPS power supply is the answer, and can be paralleled for both redundancy and capacity using patented Powerware Hot Sync UPS technology. In addition to offering surge protection and backup power, the Powerware 9315 UPS power system delivers full uninterruptible power protection against all nine common problems.

  • Delivers increased usable power capacity via optional 0.9 output power factor on the Powerware 9315 200-500 and 400-500 and 750 kVA
  • Serial and X-slot Communication Card enabled.
  • Provides flexible runtime options for your application
  • Isolates connected equipment from all incoming power problems to provide the highest degree of protection with online, double-conversion technology
  • Maintains and monitors battery health continuously with DC Expert; dynamically updates information on battery time remaining
  • Integrates seamlessly with generators by using an intelligent input filter
  • Reinforces system reliability by reducing points-of-failure by incorporating reduced component count with its innovative design
  • Starts up with the push of a button and displays UPS status information on its monitor panel
  • Incorporates connectivity products to fit various environments and applications
  • Keeps you informed by sending notification for power and UPS events that you select
  • Sends clear output signal using intelligent controls with digital signal processing (DSP)
  • Increases system reliability and ensures perfect output power by using true pulse width modulation (PWM) to enable the Insulated Gate Bipolar
  • Transistors (IGBT) to switch at their highest capacity
  • Eliminates system-level single point-of-failure with Powerware Hot Sync patented paralleling technology

Input Specifications
Voltage Range  +10% to -15%
Frequency Range  +/-5%
Surge Protection  Meets ANSI C62.41, Category A & B, EN 50091-2 and EN 50082-2
Power Factor  0.95 Typical at full load with input filter
Output Specifications
Voltage Regulation Better than +/- 1%
Voltage THD  Less than 5% (100% nonlinear load); Less than 3% (100% linear load)
Transient Response  Less than 5% for 100% load, step full recovery within 1 cycle
Frequency Regulation (Free Run) +/- 0.005 Hz
Frequency Sync Range +/- 0.5 Hz
Frequency Slew Rate 1 Hz/sec.
Load Crest Ratio 3:1
Safety (pending) UL 1778 Listed
CUL CAN/CSA C22.2NO.107.1-M91 Listed EN 50091-1
All Cabinets provide seismic mounting features, selectable DC ground fault detection capability
Environmental
Audible Noise  <75 dBA at 1 meter
Ambient Operating Temperature  0C to 40C
Ambient Storage Temperature  -20C to 70C
Altitude 5000 ft. (1500 m) at 40C without derating
Relative Humidity  5-95% non-condensing
EMC Meet FCC Class A, EN 50091-2 (CISPR 22, Class A, Restricted Access)
Electrostatic Discharge Withstands 25kV without damage or disturbance to load

Powerware 9315 200-500kVA UPS Technical Specifications:

200-300kVA 400-500kVA
Input Specifications
Frequency Range (60Hz) 57-64 Hz
(50Hz) 47-53 Hz
(60 Hz) 57-64 Hz
Surge Protection Meets ANSI C62.41, Category A & B
EN 50091-2 and EN50082-2
Meets ANSI C62.41, Category A & B
EN 50091-2 and EN50082-2
Power Factor 0.95 Typical at full load with input filter 0.95 Typical at full load with input filter
Output Specifications
Voltage Regulation Better than +/- 1% Better than +/- 1%
Voltage THD Less than 5% (100% nonlinear load); Less than 3% (100% linear load) Less than 5% (100% nonlinear load);
Less than 3% (100% linear load)
Transient Response Less than 5% for 100% load, step full recovery within 1 cycle (2.5 ms) Less than 5% for 100% load, step full recovery within 1 cycle
Frequency Regulation (Free Run) +/- 0.005 Hz (Free Run) +/- 0.005 Hz
Frequency Sync Range +/- 0.5 Hz +/- 0.5 Hz
Frequency Slew Rate 1 Hz/sec. 1 Hz/sec.
Load Crest Ratio 3:1 3:1
Power Factor 0.9 (Optional)
Battery
Battery Type Sealed, maintenance-free lead acid Sealed, valve regulated lead acid
Recharge time 10-12x discharge to 95% capacity 10-12x discharge to 95% capacity
Safety UL 1778 Listed
CUL CAN/CSA C22.2NO.107.1-M91 Listed
All Cabinets provide seismic mounting features selectable DC ground fault detection capability
UL 1778 Listed
CUL CAN/CSA C22.2NO.107.1-M91 Listed
All Cabinets provide seismic mounting features selectable DC ground fault detection capability
Environmental
Audible Noise <65 dBA at 1 meter <72 dBA at 1 meter
Ambient Operating Temperature 0C to 40C 0C to 40C
Ambient Storage Temperature -20C to +70C -20C to +70C
Altitude 5000 ft. (1500 m) without derating 5000 ft. (1500 m) without derating
Relative Humidity 5-95% non-condensing 5-95% non-condensing
EMI Suppression/EMC Meet FCC Class A, Subpart J of Part 15 and
EN 50091 (CIPR22,ClassA)
Meet FCC Class A, Subpart J of Part 15 and
EN 50091-2 (CIPR22,ClassA)
Electrostatic Discharge Withstands 25 kV without damage or disturbance to load Withstands 25kV without damage or disturbance to load

Model Selection Guide 500-600kVA

9315-750 9315-750/625
Input Voltage  volts 480 600 480 600
Output Voltage  volts 480 600 480 600
Input Voltage Range
Minimum  volts 408 510 408 510
Maximum  volts 528 660 528 600
Input/Output Frequency Hz 60 60 60 60
AC Input (with input filter)
Nominal Amps amps 913 730 761 609
Maximum Amps amps 1141 913 951 751
Bypass Input
amps 902 722 752 601
AC Input (without input filter)
Nominal Amps amps 902 722 752 601
 10 minutes max amps 1128 902 940 752
DC Link
Nominal DC Voltage  volts 384 384 384 384
Float Voltage  volts 432 432 432 432
End of Discharge  volts 320 320 320 320
Nominal Amps amps 1954 9554 1628 1628
Physical Attributes (w/o batt.)
Single Module RT Configurations
Installed Weight lbs 13200 13200 13200 13200
 Installed Width in 149 149 149 149
 Multi module Configurations
 Installed Weight lbs 12600 12600 12600 12600
 Installed Width in 126 5/8 126 5/8 126 5/8 126 5/8
System Efficiencies
 100% Load % 94 94 94 94
 75% Load % 94 94 94 94
 50% Load % 93 93 93 93
Full Load Heat Dissipation
 BTU/Hr. (x1000) 130.8 130.8 109.0 109.0
KCal/Hr. (x1000) 33.0 33.0 27.5 27.5
Inverter Efficiency (Full Load) % 95 95 95 95

Model Selection Guide 200-300kVA

9315-200 9315-250
/200
9315-250  9315-225  9315-300
/225
9315-300
 200 kVA
/160 kW
 200 kVA
/160 kW
 250 kVA
/200 kW
 225 kVA
/180 kW
 225 kVA
/180 kW
 300 kVA
/240 kW
Input Voltage  volts 400 400 400 208 480 480 480 600 480 600
Output Voltage  volts 400 400 400 208 208 480 480 600 480 600
Input Voltage Range
Minimum  volts 340 340 340 177 408 408 408 510 408 510
Maximum  volts 440 440 440 229 528 528 528 660 528 660
Input/Output Frequency Hz 50/60 50/60 50/60 60 60 60 60 60 60 60
AC Input (with input filter)
Nominal Amps amps 254 245 318 544 245 245 245 200 326 267
Maximum Amps amps 317 306 397 6880 306 306 306 250 408 333
Bypass Input amps 290 290 360 800 360 360 360 294 480 392
AC Input (without input filter)
Nominal Amps amps 288 288 374 640 288 288 288 236 384 314
 10 minutes max amps 360 360 360 800 360 360 360 294 480 392
DC Link
Nominal DC Voltage  volts 420 420 420 480 480 480 480 480 480 480
Float Voltage  volts 473 473 473 540 540 540 540 540 540 540
End of Discharge  volts 351 351 351 401 401 401 401 401 401 401
Nominal Amps amps 457 457 571 450 450 450 450 450 600 600
Physical Attributes (w/o batt.)
 Installed Weight lbs 3812 4177 4177 6363 3863 3863 4177 6677 4177 6677
 Installed Width in 65 65 65 103 65 65 65 93 65 93
System Efficiencies
 100% Load % 92 92 91 91 92 92 92 91 92 91
 75% Load % 92 90 90 91 92 92 92 90 92 91
 50% Load % 92 88 89 90 91 91 91 88 92 89
Full Load Heat Dissipation
 BTU/Hr. (x1000) 47.8 47.8 59.7 61.8 53.7 46.2 39.2 61.7 71.7 82.4
KCal/Hr. (x1000) 12.5 12.5 15.0 15.5 13.5 11.6 9.8 15.5 18.1 20.8
Inverter Efficiency (Full Load) % 93 93 93 93 92 93 94 93 93 93

Model Selection Guide 400-500kVA

9315-400 9315-400/300 9315-500  9315-500/400
 400 kVA/320 kW  300 kVA/240 kW  500 kVA/400 kW  400 kVA/320 kW
Input Voltage  volts 400 400 480 480 480 208
Output Voltage  volts 400 400 480 480 208 208
Input Voltage Range
Minimum  volts 340 340 408 408 408 177
Maximum  volts 440 440 528 528 528 229
Input/Output Frequency Hz 50/60 50/60 60 60 60 60
AC Input (with input filter)
Nominal Amps amps 508 381 556 445 445 1025
Maximum Amps amps 635 476 640 560 560 1280
AC Input (without input filter)
Nominal Amps amps 598 448 654 523 523 N/A
 10 minutes max amps 747 560 800 640 640 N/A
DC Link
Nominal DC Voltage  volts 420 420 480 480 480 480
Float Voltage  volts 473 473 540 540 540 540
End of Discharge  volts 351 351 401 401 401 401
Nominal Amps amps 914 686 1000 800 800 800
Physical Attributes (w/o batt.)
 Installed Weight lbs 6100 6100 6100 6100 10100 14100
 Installed Width in 74 74 74 74 123 172
System Efficiencies
 100% Load % 94 94 94 92 91 90
 75% Load % 94 94 94 92 91 90
 50% Load % 94 93 94 91 90 89
Full Load Heat Dissipation
 BTU/Hr. (x1000) 69.8 52.3 87.2 107.3 107.3 119.0
KCal/Hr. (x1000) 17.6 13.2 22 24.1 27.1 30.0
Inverter Efficiency (Full Load) % 95 95 95 92.5 92.5 92.5

© 2021 Power Tech Private Limited | Theme by Hope Group Of Companies | All Rights Reserved.