Accuracy Specifications |
DC millivolts |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
± ([% of reading] + [counts]): 2.0% + 3 |
|
DC volts |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.00 V / 0.1 V |
|
Auto volts |
Range: |
600.0 V |
Resolution: |
0.1 V |
Accuracy: |
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
|
AC millivolts1 true-rms |
Range: |
600.0 mV |
Resolution: |
0.1 mV |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms |
Range/Resolution: |
6.000 V / 0.001 V |
Range/Resolution: |
60.00 V / 0.01 V |
Range/Resolution: |
600.0 V / 0.1 V |
Accuracy: |
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity |
Range: |
600 Ω |
Resolution: |
1 Ω |
Accuracy: |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
Ohms |
Range/Resolution: |
600.0 Ω / 0.1 Ω |
Range/Resolution: |
6.000 kΩ / 0.001 kΩ |
Range/Resolution: |
60.00 kΩ / 0.01 kΩ |
Range/Resolution: |
600.0 kΩ / 0.1 kΩ |
Range/Resolution: |
6.000 MΩ / 0.001 MΩ |
Accuracy: |
0.9 % + 1 |
Range/Resolution: |
40.00 MΩ / 0.01 MΩ |
Accuracy: |
1.5 % + 2 |
|
Diode Test |
Range/Resolution: |
2.000 V / 0.001 V |
Accuracy: |
0.9% + 2 |
|
Capacitance |
Range/Resolution: |
1000 nF / 1 nF |
Range/Resolution: |
10.00 μF / 0.01 μF |
Range/Resolution: |
100.0 μF / 0.1 μF |
Range/Resolution: |
9999 μF / 1 μF |
Range/Resolution: |
100 μF to 1000 μF |
Accuracy: |
1.9% + 2 |
Range/Resolution: |
> 1000 μF |
Accuracy: |
5% + 20% |
|
LoZ capacitance |
Range: |
1 nF to 500 μF |
Accuracy: |
10% + 2 typical |
|
Temperature2 (Type-K thermocouple) |
Range/Resolution: |
-40 °C to 400 °C / 0.1 °C |
Accuracy: |
1% + 102 |
Range/Resolution: |
-40 °F to 752 °C / 0.2 °F |
Accuracy: |
1% + 182 |
|
AC amps true-rms (45 Hz to 500 Hz) |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.5% + 3 |
|
20 A continuous overload for 30 seconds max |
|
DC amps |
Range/Resolution: |
6.000 A / 0.001 A |
Range/Resolution: |
10.00 A / 0.01 A |
Accuracy: |
1.0% + 3 |
|
20 A continuous overload for 30 seconds max |
|
Hz (V or A input)2 |
Range/Resolution: |
99.99 Hz / 0.01 Hz |
Range/Resolution: |
999.99 Hz / 0.1 Hz |
Range/Resolution: |
9.999 Hz / 0.001 Hz |
Range/Resolution: |
50.00 Hz / 0.01 Hz |
Accuracy: |
0.1% + 2 |
|