Fluke 435 Three Phase Power Quality Analyzer Kit (Series 1)
The Only Class A Power Quality Troubleshooter!
The Fluke 435 three-phase power quality analyzer help you locate, predict, prevent and troubleshoot problems in three- and single- phase power distribution systems. Troubleshooting is faster with on-screen display of trends and captured events, even while background recording continues.
The Fluke 435 offers unique features like AutoTrend, which records everything on the screen automatically; System-Monitor, a quick diagnosis of system performance against user defined limits; Logger Function with multi-parameter logging; and Mains Signaling, measures interference from ripple control signals at specific frequencies. These features help to quickly diagnose problems and build benchmarks for predictive maintenance.
The new IEC standards for flicker, harmonics, and power quality are built right in to take the guess work out of power quality.
Simple to use with immediate results
Designed for power quality specialists as well as electricians and plant technicians working in industrial, healthcare, business, and public services settings, the Fluke 435 has functions typically only found on expensive power recorders. Yet its menu-driven interface allows users to be hooked up and recording in minutes.
Full measurement capability and the highest safety rating
Fully Class A Compliant – conduct tests according to the stringent international IEC 61000-4-30 Class A standard. With a CAT III, 1000 V / CAT IV, 600 V safety rating the Fluke 435 can measure all phases, neutral and ground on virtually every connection in a low voltage electrical distribution system. The meter’s measurement capabilities encompass all power system parameters including true-rms voltage and current, frequency, power, power consumption (energy), unbalance and flicker. They also automatically capture events like transients (as fast as 5 microseconds and as high as 6kV), interruptions, rapid voltage changes and dips and swells.
Rugged design for field use
Optimized for mobile applications, these rugged instruments operate up to seven hours on a single battery charge. The large data (16 MB) memory stores up to 50 screens. A detailed, user-configurable long-time recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all 4 phases with selectable averaging time down to 0.5 seconds. Enough memory is available to record 400 parameters with 1 minute resolution for up to a month, all of which can be transferred to a PC via FlukeView® software for analysis or use in reports.
If any of these situations apply to you, then this tool is for you:
- Frontline Troubleshooting – Quickly diagnose problems on-screen to get your operation back online
- Predictive Maintenance – Detect and prevent power quality issues before they cause downtime
- Quality of Service Compliance – Validate incoming power quality at the service entrance
- Long-term Analysis – Uncover hard-to-find or intermittent issues
- Load Studies – Verify electrical system capacity before adding loads
- Energy Assessments – Quantify energy consumption before and after improvements to justify energy saving device
What’s Included:
- Fluke C435 Water-tight hard case with rollers
- Fluke i430s 4x 3000A flexible current clamps, CAT IV 600 V rated
- Fluke TLS430 5 Test leads, 4 black, 1 green
- Fluke BC430 Battery Charger Eliminator
- FlukeView Software SW43W
- Fluke PowerLog Software
- Fluke OC4USB Optical Cable for USB
- Fluke WC100 Color localization set
- Getting Started printed
- User Manual (CD-ROM)
- Auto Power Off
- Auto Transient Capture
- Auto Trend Recording
- Backlight
- Class A Compliance
- Class A Compliant
- Datalogging
- Display color graphical
- Display color display
- Display Hold
- Included CT Rating 3000a
- Included CT Type flexible
- Included CTs 4x 3000a flexible cts
- Inrush Current
- Mains Signalling
- Min/Max/Avg
- Number Included CTs 4
- Phasor Diagrams
- Report Generator
- Single Phase
- Software
- Statistical Analysis
- System Monitor
- Three Phase
- Transient Event Capture
- Transient Events
- True RMS
- Unbalance
- User Defined Logging
- Waveform Capture
- Waveform Display
Battery Life | 7 hours |
Battery Type | nimh |
CAT III Rating | 1000v |
CAT IV Rating | 600v |
Current AC Accuracy | 1% + 5 counts |
Current DC Accuracy | 0.10% |
Current Inputs | 4 |
Dimensions | 256 mm x 169 mm x 64 mm (10 in x 6.5 in x 2.5 in) |
High Speed Capture Rate | 200 |
IP Rating | ip51 |
Memory | 16 |
Operating Temperature | 0 °c to +50 °c (32 °f to 122 °f) |
Sample Rate | 20.48 |
Storage Temperature | -20 °c to +60 °c (-4 °f to +140 °f)` |
Typical Recording Period | 30 |
Voltage AC Accuracy | 0.1% vnom |
Voltage DC Accuracy | 0.10% |
Voltage Inputs | 4 |
Weight | 2 kg (4.5 lb) |